Not all KP3S power supplies have temperature-controlled fans - even if the writing on the case says it does. This will only turn on the fan when needed (temp > 45 degree C) and cut down on much of the noise of this printer.
- KSD9700 Normally Open Thermostat.
- Final install should look similar to this:
- Install the end of the temp sensor inside the circle similar to this: